Performing an electronically check to find a refrigerant leak on an AC condenser
New AC unit installation
Diagnosing airflow issues on a gas furnace with high limit trips
While doing a routine maintenance on a gas furncae, we found rusty seams on a heat exchanger
Performing a gas furnace, safety inspection, making sure that the carbon monoxide levels in the flu aren't out of range
Diagnosing thermostat issues on a no cooling service call
Checking pressures on an AC condenser during a routine maintenance
Gas furnace replacement
Found and repaired burnt terminals on an air conditioning condenser. No cooling service call
Found and cleared a plugged water trap on a high-efficiency gas furnace on a no heat service call
Checking gas furnace operation on a routine, gas furnace maintenance
Check in the evaporator on a AC service. Call to make sure that it's not dirty.
Found a crack in the heat exchanger on a gas furnace maintenance
Gas furnace replacement
Diagnosing a plugged pilot assembly on a gas furnace
AC compressor changed out on a condenser
Replacement of an AC system
Replaced a shorted contactor on a no AC service call
New air conditioning change out
New gas furnace replacement
Compressor replacement on an AC condenser
Evacuation of an air-conditioning system after a compressor replacement
Adding refrigerant to a low charge AC system
Blower motor and blower wheel replacement on a gas furnace
Replaced a draft blower assembly on a gas furnace
Checking flame signal on a routine gas furnace service call
Replace zone board that was not operating on one of the zones
Adding refrigerant to a low charge, air conditioning system on a nighttime service call
Replacing a piston style metering device that was restricted on an air conditioning system
Checking pressures on an air-conditioning system during a routine, air conditioning maintenance
Found a partially dirty blower wheel, contributing to low airflow on a gas furnace
ECM blower motor replacement on a gas furnace
Performing a combustion analysis on a hot water heater
Previously condemned by another company I brought a 45 year old air conditioner back to life by replacing the condenser fan motor save the customer thousands
Air conditioning condenser replacement
Performing a combustion analysis on a routine, gas furnace maintenance
Checking pressures on an air conditioning system during a routine maintenance
New gas furnace replacement
New gas furnace replacement
Diagnosing an air conditioning system with not enough cooling found low, refrigerant charge
Checking the flame signal of a flame sensor after cleaning it for a no heat service call on a gas furnace
Found a gas, furnace, burning dangerously high levels of carbon monoxide on a routine, gas furnace maintenance
Checking gas pressure at the gas valve of a furnace during a no heat service call
Found a cracked heat exchanger while performing an evaporator coil change out
Testing a run capacitor on a routine maintenance to make sure it's not out of range